Description
L-Series Breathers are available with 100% silica gel. These breathers include an in-line filter/dryers that remove water vapor and solid contaminants from air exhaust lines, low pressure compressed air lines, vacuum lines, and other in-line airflow applications where clean, dry air is required. Air enters the filter/dryer in one end and is clean and dry when leaving the other end. Water vapor and solid particles down to 2 micron are removed. L-Series is rated up to 60 psi and mounted on the regulated side of the air line.
SPECIFICATIONS
Model | Height inches (cm) | Diameter inches (cm) | Both Ends Connection | Silica Gel lbs (kg) | Carbon Weight lbs (kg) | Maximum Adsorptions Capacity fl. ounces (mL) | Maximum Air Flow cfm | Maximum Reservoir Fluid Flow gpm | Type of Medium |
---|---|---|---|---|---|---|---|---|---|
L-50 | 3.25 (8.2) | 3 (7.6) | ½” FNPT | 0.6 (0.27) | N/A | 3.68 (109) | 10 | 75 | 100% Silica Gel |
L-143 | 5.5 (14.0) | 3.25 (8.3) | ½” FNPT | 0.8 (0.4) | N/A | 4.91 (145) | 10 | 75 | 100% Silica Gel |