VACUUM DEHYDRATION SYSTEMS
Call For Pricing
Typical Applications
- Filtering Pulp and Paper lube systems
- Filtering steam turbine lube systems
- Filtering hydraulic reservoirs
- Filtering rolling mill lube tanks
- And many other industrial applications containing oil
Standard Features
Process: Vacuum Dehydration
Chamber: Pall Dispersion Rings; never have to get in chamber to change filter elements
Chamber Vacuum: Adjustable; Ideal range is 22-27” Hg
Fluid Temperature: Factory is set at 145°F and is adjustable up to 165°F
Filtration: 1 ea – 6×18 Filter Element
Seal Material(s): Buna N, Viton, EDPM or EPR
Max Fluid Viscosity: ISO 680 or 4250 SUS
Continuous Heater Flow: Minimum 2-5 GPM continuous flow through heater to prevent oil coking
Console Remote Alarm: 250 V, 10 AMP dry contact rating
Wheel Configuration: Caster wheels, pneumatic tires, fork lift pockets or floor mount
Water Removal Rate: The removal rate of water will vary depending on fluid properties and application parameters
Moisture Content Monitor: Measures in % and will shut down when it reads 0%
Operator Interface Panel Features: One button on/off Auto Shut down if operating parameters move outside of limits Panel displays all conditions; including causes and remedies Help Screen
Technical Specifications
Flow Rate: 5 GPM or 15 GPM
Vacuum Pump Flow Rate: 13 CFM
Heater Capacity: 3 KW @ 15wsi (FD-5) 18 KW @ 15wsi (FD-15)
Motors: Electric, 480 VAC, 3 Phase
Plumbing: Inlet: 1-1/2” FNPT, Outlet: 1-1/2” FNPT
Approximate Dry Weight: 950 lbs (FD-5), 1300 lbs (FD-15)
Dimensions: 44.5”L x 30.5”W x 68”H (FD-5), 54”L x 31”W x 78”H (FD-15)
Reviews